S. Guatelli1 on behalf of the Geant4 Medical Simulation Benchmarking Group and of the Geant4 Advanced Examples Working Group
1Centre For Medical and Radiation Physics, University of Wollongong, Wollongong, Australia.
Background: In the past few years, we developed G4-Med, a fully automated benchmarking and regression testing suite of Geant4 for bio-medical applications [2], for validation and performance monitoring.
Material and Methods: The testing suite currently includes 19 tests, from basic physical quantities (e.g. stopping powers, cross sections, dose point kernels) to tests of clinical medical physics applications, such as hadron therapy, brachytherapy, external electron beam therapy and mammography. The tests have been integrated in the geant-val platform [3] and are executed for Geant4 development tags and public releases. The Geant4 results are compared to reference data.
Preliminary results: At the conference, we will show the results of the regression testing of the G4-Med tests with Geant4 11.0, against simulation results obtained with previous Geant4 releases (10.5 and 10.6) and the reference data adopted in each test. Significant improvement has been observed in the multiple scattering and in the modelling of bremsstrahlung (see fig. 1).
The talk will conclude with a short summary on the advanced examples of Geant4 for medical physics. Approximately 50% of them are dedicated to medical physics, spanning from dosimetry in X-ray radiotherapy, brachytherapy and hadrontherapy to radiation protection in anthropomorphic phantoms.