Initial Reconstruction Results from a Simulated Adaptive Small Animal C Shaped PET/MR Insert

19 mag 2015, 16:00
1O 30m
Room Elena

Room Elena

Poster 5 - Preclinical MR-PET Session 8 - Poster Session I

Relatore

Nikos Efthimiou (Technological Educational Institute of Athens)

Descrizione

Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standart geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

Autore principale

Nikos Efthimiou (Technological Educational Institute of Athens)

Coautore

Dr. Charalampos Tsoumpas (Division of Biomedical Imaging, University of Leeds, Leeds, United Kingdom) Prof. George Loudos (Department of Biomedical Engineering, School of Technological Applications, Technological Educational Institute of Athens) Sig. Panagiotis Papadimitroulas (Department of Medical Physics, School of Medicine, Univ. of Patras) Sig.na Theodora Kostou (Department of Medical Physics, School of Medicine, Univ. of Patras)

Materiali di presentazione

Non sono ancora presenti materiali