17–20 May 2015
La Biodola, Isola d'Elba
Europe/Rome timezone

Attenuation Correction for Hybrid MR/PET Scanners: a Comparison Study

19 May 2015, 16:00
1h 30m
Room Elena

Room Elena

Poster 3 - Advances in MR-PET and MR-SPECT software and quantification Session 8 - Poster Session I

Speaker

Elena Rota Kops (Forschungszentrum Juelich, Juelich, Germany)

Description

Attenuation correction of PET data acquired in hybrid MR/PET scanners is still a challenge. Different methods have been adopted by several groups to obtain reliable attenuation maps (mu-maps). In this study we compare three methods: MGH, UCL, Neural-Network. The MGH method is based on an MR/CT template obtained with the SPM8 software. The UCL method uses a database of MR/CT pairs. Both generate mu-maps from MP-RAGE images. The feed-forward neural-network from Juelich (NN-Juelich) requires two UTE images; it generates segmented mu-maps. Data from eight subjects (S1-S8) measured in the Siemens 3T MR-BrainPET scanner were used. Corresponding CT images were acquired. The resulting mu-maps were compared against the CT-based mu-maps for each subject and method. Overlapped voxels and Dice similarity coefficients, D, for bone, soft-tissue and air regions, and relative differences images were calculated. The true positive (TP) recognized voxels for the whole head were 79.9% (NN-Juelich, S7) to 92.1% (UCL method, S1). D values of the bone were D=0.65 (NN-Juelich, S1) to D=0.87 (UCL method, S1). For S8 the MHG method failed (TP=76.4%; D=0.46 for bone). D values shared a common tendency in all subjects and methods to recognize soft-tissue as bone. The relative difference images showed a variation of -10.9% - +10.1%; for S8 and MHG method the values were -24.5% and +14.2%. A preliminary comparison of three methods for generation of mu-maps for MR/PET scanners is presented. The continuous methods (MGH, UCL) seem to generate reliable mu-maps, whilst the binary method seems to need further improvement. Future work will include more subjects, the reconstruction of corresponding PET data and their comparison.

Primary author

Elena Rota Kops (Forschungszentrum Juelich, Juelich, Germany)

Co-authors

Mr Andre Santos Ribeiro (Imperial College London, London, UK) Dr Christoph W Lerche (Forschungszentrum Juelich, Juelich, Germany) Prof. Gerald Antoch (Heinrich-Heine-University Duesseldorf, Duesseldorf, Germany) Dr Hubertus Hautzel (Heinrich-Heine-University Duesseldorf, Duesseldorf, Germany) Dr Liliana Caldeira (Forschungszentrum Juelich, Juelich, Germany) Mr Mathias Lukas (Technische Universitaet Muenchen, Munich, Germany) Prof. N. Jon Shah (Forschungszentrum Juelich, Juelich, Germany)

Presentation materials

There are no materials yet.