Laboratory PolyCO Based X-ray Imaging of High-Pressure Fuel Sprays

25 Sept 2012, 18:40
15m
Hotel Calabona (Hotel Calabona)

Hotel Calabona

Hotel Calabona

X-ray Channeling & X-ray Optics S4.2 X-ray Channeling & X-ray Optics

Speaker

Dr Luigi Allocca (Istituto Motori - C.N.R.)

Description

Table-top experiment using a microfocus X-ray source for radiography and tomography has been used for investigating the structure of a gasoline pulsed spray flowing from a GDI injector for automotive applications. A Cu Kα X-ray source at 8.048 keV in combination with a polycapillary halflens has been used to focus the radiation on the spray while a CCD detector collected the resulting signal. The fuelling apparatus feeds an injector inserted in a high-pressure rotating device actuated with angular steps Delta(Teta)= 1°. The acquisition has been carried out on 180° angular trip at the injection pressure of 8.0 MPa. The image processing has permitted sinogram reconstructions of the jets by slices allowing a 360° spray access to the spatial and temporal distribution of the fuel downstream the nozzle tip.

Primary author

Dr Luigi Allocca (Istituto Motori - C.N.R.)

Co-authors

Dr Dariush Hampai (LNF - INFN) Dr Luca Marchitto (Istituto Motori - CNR) Prof. Sultan Dabagov (INFN Laboratori Nazionali di Frascati)