ALICE ITS3 discussion
Wednesday 11 Jan 2023, 11:00
→
13:00
Europe/Rome
Aula Wick
Aula Wick
1
Timing resolution analysis method
Minutes
Speaker
:
Bong-Hwi Lim
(
Istituto Nazionale di Fisica Nucleare
)
[ITS3-WP3]-DCFD_update.pdf
CAEN AN3251_Time_Mes_CAEN_Digitizer.pdf
dCFD_paper.pdf
Update_APTS-OA_TestBeamData_Analysis2.pdf
CFD method
The analysis method is in a stable state.
Shared with Miko and confirmed the current definitions
Current definitions:
Baseline: t_0 - 17.5 ns ~ t_0 - 15 ns (2.5ns range)
Underline: t_0 + 21.25 ns ~ t_0 + 22.5 ns (1.25 ns range)
Keep it as a main reference.
Digital CFD (dCFD) method
Studied with 3 different parameters (k, d, L)
Conclusion: Impossible to select parameters in this method.
Discussion:
dCFD method - it looks like it was used when the signal has always the same properties (amplitude, fall time, width ...).
Our case is not like that.
In this case, we have to study about this method:
Is it really used only for the constant signal?
Can dCFD method be improved if we split the signal width (fall time)?
2
Gain calibration
Speaker
:
Stefania Perciballi
(
Istituto Nazionale di Fisica Nucleare
)
Gain Correction.pdf
3
Test beam track reconstruction
Speaker
:
Chiara Ferrero
(
Istituto Nazionale di Fisica Nucleare
)
4
Discussion
Speakers
:
Stefania Beole'
(
Istituto Nazionale di Fisica Nucleare
)
,
Umberto Savino
(
Istituto Nazionale di Fisica Nucleare
)