-
Dr Igor Chirikov-Zorin (JINR)29/05/2015, 16:45S9 - CalorimetryPosterA nine-channel photodetector unit with micropixel avalanche photodiodes (MAPD) and precision thermostabilization based on the compact Peltier element is designed and constructed. MAPD-3N with superhigh pixel density 15000 per square mm and area 3×3 mm manufactured by the Zecotek Company were used.Go to contribution page
-
Dr Giulio Usai (Arlington UT)29/05/2015, 16:46S9 - CalorimetryPosterThe Tile Calorimeter (TileCal) is the hadronic calorimeter of ATLAS covering the central region of the ATLAS experiment. TileCal will undergo a major replacement of its on- and off-detector electronics for the high luminosity programme of the LHC in 2024. The calorimeter signals will be digitized and sent directly to the off-detector electronics, where the signals are reconstructed and...Go to contribution page
-
Raffaella Donghia (LNF)29/05/2015, 16:47S9 - CalorimetryPosterAs an alternative of the crystal choice for the Mu2e calorimeter, we have tested single crystals of pure CsI in combination with large area MPPC from Hamamatsu. The MPPC under consideration, consisting of an array of 16 3$\times$ 3 mm$^2$ cells, 50 $\mu$m pixels, grants an active area of 12$\times$12 mm$^2$ and has an improved PDE reaching $\sim$ 40 \% down to 250 nm thus well...Go to contribution page
-
Graziano Venanzoni (LNF)29/05/2015, 16:48S9 - CalorimetryPosterThe muon anomaly (g-2)/2 has been measured to 0.54 parts per million by E821 experiment at Brookhaven Lab, and at present there is a 3 to 4-standard deviation difference between the SM and experimental values. A new muon (g - 2) experiment, E989, is being prepared at Fermilab that will improve the experimental error by a factor of four to clarify this difference. A central component to...Go to contribution page
-
Simone Gelli (R)29/05/2015, 16:49S9 - CalorimetryPosterA sampling calorimeter using cerium fluoride scintillating crystals as active material, interleaved with absorber plates made of tungsten,and read out by wavelength-shifting fibers has been studied as a calorimeter option for detectors at the upgraded LHC collider at CERN. A prototype has been exposed to high-energy electron beams at the CERN SPS H4 beam line, as well as to lower-energy beams...Go to contribution page
-
Paolo Meridiani (ROMA1)29/05/2015, 16:50S9 - CalorimetryPosterIMCP is an R&D project aimed at the exploitation of secondary emission of electrons from the surface of micro-channel plates (MCP) for fast timing of showers in high rate environments. The usage of MCPs in "ionisation" mode has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing...Go to contribution page
-
Yi-Fan Jin (University of Tokyo)29/05/2015, 16:52S9 - CalorimetryPosterBELLE II is the upgrade of BELLE by 40 times luminosity, investigating the CP-violation effects. In order to cope with the extremely high luminosity at Belle II, utilizing fast pure CsI scintillation crystals at end cup of ECL has been proposed. Silicon avalanche photodiodes (APD) are considered as a candidate of photosensitive elements to get the acceptable level of the electronic noises. In...Go to contribution page
-
Liyuan Zhang (California Institute of Technology)29/05/2015, 16:53S9 - CalorimetryPosterThis paper reports charged hadron induced radiation damage in crystal scintillators using 800 MeV proton beam at the WNR facility of LANSCE. A 20 cm long LYSO crystal, a 14 cm long CeF3 crystal and four liquid scintillator based sealed quartz capillaries were irradiated to the level of 1014 p/cm2 by 800 MeV protons in the WNR facility of LANSCE. The results show that the emission weighted...Go to contribution page
-
Mr Chunhui Zhang (Utrecht University), Prof. Thomas Peitzmann (Utrecht University/Nikhef)29/05/2015, 16:54S9 - CalorimetryPosterA compact high-granularity electromagnetic calorimeter prototype has been built to perform generic R&D for an upgrade proposal of a forward calorimeter (FoCal) in the ALICE experiment, which should have very good gamma/π0 discrimination capabilities. The prototype is a Si/W sampling calorimeter using CMOS sensors of the MIMOSA type with a pixel pitch of 30 micron and binary readout with a...Go to contribution page
-
Dr Erik Ramberg (Fermilab)29/05/2015, 16:55S9 - CalorimetryPosterWe present a study of micro-channel plate photomultipliers (MCP-PMT) as the active element of an electromagnetic shower maximum (SM) detector. Results for Photek 240 and Photonis XP85011 MCP-PMT devices were obtained at the Fermilab Test Beam Facility. The time resolutions obtained for this new type of SM detector is at the level of ~12 ps for Photek 240 and ~27 ps for Photonis XP85011 with...Go to contribution page
-
Mr Vasiliy Shebalin (Budker Institute of Nuclear Physics)29/05/2015, 16:56S9 - CalorimetryPosterCMD-3 is a general purpose detector designed to study $e^+e^-$ annihilation in hadrons in the wide energy range, $E_{c.m.s}=0.3\div2$~GeV. Since 2010 CMD-3 collected data at the $e^+e^-$ collider VEPP-2000 in the Budker Institute of Nuclear Physics. VEPP-2000 collider with $10^{32}cm^{-2}s^{-1}$ luminosity is the only present collider which covers its energy range. The calorimetry at the...Go to contribution page
-
Andrea Longhin (LNF)29/05/2015, 16:57S9 - CalorimetryPosterNeutrino cross section measurements are an essential requirement for the next generation of neutrino oscillation experiments and they are presently limited by uncertainties on neutrino fluxes. In [1] we propose to instrument a neutrino decay tunnel to detect large angle positrons and tag the three-body semileptonic $K^+ \to e^+ \pi^0 \nu_e$ decays. In such a facility the absolute...Go to contribution page
-
Donato Nicolo' (PI)29/05/2015, 16:58S9 - CalorimetryPosterThe liquid xenon calorimeter of the MEG experiment at PSI is designed to have a percent-level resolution at a photon energy of $52.8~$MeV. To measure its performance, stability and uniformity it is mandatory to have a calibration source as close as possible to this energy. The charge exchange reaction of negative pions at rest on protons produces both mono-energetic 129~MeV photons and a...Go to contribution page
-
Mr Laszlo Papp (Physik-Department und Excellence Cluster Universe, Technische Universität München, Germany)29/05/2015, 16:59S9 - CalorimetryPosterThe Ce-SOX experiment is being built to clarify neutrino anomalies by observing possible short distance neutrino oscillations. For this purpose, a 100 kCi 144Ce-144Pr antineutrino generator will be placed under the BOREXINO detector at the Laboratori Nazionali del Gran Sasso in Italy. Thanks to its large size and very low background, BOREXINO is an ideal detector to discover or refute eV-scale...Go to contribution page
-
Graziano Venanzoni (LNF)29/05/2015, 17:00S9 - CalorimetryPosterThe electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 -- 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse...Go to contribution page
-
Mr Christoph Rosenbaum (II. Physikalisches Instiut, University Gießen, Germany)29/05/2015, 17:01S9 - CalorimetryPosterThe PANDA detector at the future FAIR facility will be used to study proton - antiproton interaction. The electromagnetic calorimeter (EMC) of the target spectrometer with its expected excellent performance and efficiency for electromagnetic probes over a wide energy range from 10 MeV up to 15 GeV, will be one of the central components to achieve the physics goals. The barrel part of the EMC...Go to contribution page
-
Simona Giovannella (INFN - LNF)29/05/2015, 17:02S9 - CalorimetryPosterA beam test of the prototype LYSO electromagnetic calorimeter for the Mu2e experiment at Fermilab has been performed at the beam test facility, BTF, of the Laboratori Nazionali di Frascati of INFN using electrons from 100 to 450 MeV. The time resolution of the 25 crystal matrix, readout by large area APD of Hamamatsu, has been measured with two techniques and compared with Monte...Go to contribution page
Choose timezone
Your profile timezone: