Weekly debrief
Weekly debreif - τ→ KL X analysis
Thursday, Oct 8th 10:30 +0200 (CEST)
Weekly Debrief — 8 October 2026
D∗ control sample — Simone
Production status
- About
105fb−1 of theKL0 sample have been processed/downloaded.
- The
KS0 grid production was unfortunately empty because anInvM selection range was mistakenly applied to theInvM2 variable.
- A smaller local sample is now being rerun at KEK to debug and validate the corrected reconstruction before relaunching the full production.
D→K∗π,
D∗→Dπ reconstruction
- The control sample reconstructs
D→K∗π andD∗→Dπ
to suppress the large combinatorial background. - Cuts applied to lower-level particles inside
reconstructDecaydo not appear to behave as intended.- Suggested solution: use the daughter wrapper to apply the cuts explicitly to the daughters of the reconstructed candidate.
- A large fraction of the current
D∗ combinatorial background should disappear once the correctK∗ mass selection is applied.
- Apply the
K∗ mass requirement directly to the reconstructedK∗ candidate.
- Define the signal window from the measured mass resolution, approximately
±3σ around the nominalK∗(892) mass.
- Define the signal window from the measured mass resolution, approximately
Signal/background definition and fit strategy
- Before defining the final
ΔM fit:
- study signal and background separately;
- use MC truth to identify the genuine
D∗ decay rather than relying only on a selection-sideband definition;
- check explicitly for possible peaking backgrounds, including radiative decays.
- Improve the MC-matching definition of the
D∗ signal so that legitimate radiative decays are not incorrectly classified as background.
- For the eventual
ΔM fit:
- check Matilde's presentation and the BaBar reference for the adopted PDF strategy;
- determine which shape parameters can be fixed and whether only the signal/background yields need to float.
Consistent
KS0 and
KL0 reconstruction
- Reconstruct the
KS0 control branch using the same constrained-momentum philosophy used for theKL0 candidates, to maximize cancellation of reconstruction-related uncertainties in the efficiency ratio.
- The ntuples store
InvM2:
- extract the physical invariant mass offline;
- retain the correct treatment of negative
InvM2 candidates rather than applying an invalid square root.
- Cross-check with the Neutral group whether an existing basf2 recoil variable can provide the needed kinematic constraint, potentially replacing the custom module.
K∗ candidates
- The two apparent
KS0π± peaks are strongly correlated with the pion charge.
- The current
KS0piplusandKS0piminusvariables should therefore not be interpreted independently over the full sample. - Display and study these variables only after selecting the correct
K∗ mass region.
Multiple candidates and immediate next steps
-
Check the treatment adopted in the BaBar analysis.
-
In particular, verify whether a
1/Ncand weighting is appropriate or whether a best-candidate selection is preferable. -
Fix and validate the
KS0 reconstruction. -
Relaunch the full
KS0 production once the local validation is successful. -
Define the
K∗ mass window from the reconstructed resolution. -
Improve the MC-truth signal definition, including radiative decays.
-
Check candidate multiplicity and the BaBar prescription.
-
Keep detailed
KL0 PDF modelling paused until the reconstruction itself is stable.
KL0 efficiency correction — updates from Performance
- The Neutral group showed a clean control sample reconstructed using the recoil technique, see slides https://agenda.infn.it/event/54026/contributions/307492/attachments/156115/240450/KL_recoil_low-E.pdf
- They derive separate data/MC corrections for the absolute
KL0 reconstruction efficiency in the ECL and KLM.
- It would be useful to compare their results directly with our
D∗-based correction.
- In our strategy, the absolute
KL0 efficiency correction should ultimately come from theKS0/KL0 comparison in theD∗ control sample.
- The comparison with the Neutral-group calibration can provide an important independent validation.
τ→KS0πν control sample — Arthur
Current question
- Reconsider whether the present control-sample definition, in which the
KS0 is masked to emulate the masked-KL0 signal reconstruction, is still the optimal choice.
- The current strategy has clear advantages:
- little direct dependence of the
qq¯ BDT onKL0 modelling;
- a natural
τ→KS0π(π0)ν control sample.
- little direct dependence of the
- Its disadvantages are:
- worse
qq¯ rejection in the signal reconstruction
- residual
τ+τ− and continuum contamination in the control sample;
- a reconstruction that differs from Michele's analysis and therefore complicates direct comparison.
- worse
Combination/blinding strategy
- There is no fundamental problem with treating
τ→KS0πXν andτ→KL0πXν as independent analyses with separate timelines and unblinding procedures. - The common reconstruction/calibration work should nevertheless be shared wherever possible.
- Combination can be performed once the two measurements are individually mature.
- The control-sample correction is based on an efficiency double ratio, so it does not by itself create a branching-fraction blinding problem.
Reconsidering the neutral-kaon masking
Motivation
A possible alternative is to restore the selected
KL0 cluster in the event-shape and event-kinematics calculation.
The main motivations are:
- improve
qq¯ discrimination;
- return to a more standard reconstruction;
- make the BDT and event definitions closer to those used by Michele;
- simplify future comparison or combination.
The original motivation for masking the
KL0 was to avoid feeding poorly modelled
KL0 quantities indirectly into the continuum BDT.
Proposed test
Do not immediately replace the current strategy. Instead compare two internally consistent configurations:
- Current masked-
K0 reconstruction
- Standard/unmasked reconstruction
For the unmasked configuration:
- restore the
KL0 cluster in the signal event-shape calculation;
- reconstruct the
KS0 control sample consistently without the corresponding masking;
- retrain the
qq¯ BDT;
- compare:
- signal efficiency;
- continuum rejection;
- BDT-output shapes;
- data/MC agreement of the BDT inputs;
- size and stability of the resulting efficiency correction.
Recommended control-sample validation
For the
τ→KS0πν control sample:
- quantify the sample purity before and after the
qq¯ BDT;
- fit the
KS0 mass in data to extract the genuine control-sample yield;
- repeat the fit in MC and compare with MC truth;
- explicitly check whether residual
qq¯ contamination biases the extracted BDT efficiency;
- compare the BDT input distributions between control sample and signal;
- if necessary, reweight the control sample to the signal kinematics before deriving the efficiency correction;
- test one or more additional
τ→KS0πXν modes as validation samples to verify that the correction is stable across the relevant phase space.
Next steps - summary
- Fix the
D∗KS0 reconstruction and complete the control-sample production.
- Produce consistent masked and unmasked versions of the
τ→KL0πXν signal andτ→KS0πν control samples.
- Perform a controlled comparison of the two
qq¯-BDT strategies.
- Derive the BDT-efficiency correction in the
KS0 control sample, with and without background subtraction.
- Check whether the correction is stable after kinematic reweighting.
- Decide whether
klmClusterKLIDshould remain in the continuum BDT based on the final corrected efficiency uncertainty, not only classifier performance.
Strategy outlook after the selection is frozen
- Derive the
KL0 reconstruction correction from theD∗ control sample and compare it with the Neutral-group result.
- Update the selected-sample composition.
- Separate residual
τ background into fake-KL0 and genuine-kaon/Vud components.
- Proceed to the data-constrained background fit and signal extraction.
- Build the response/unfolding procedure only after the reconstructed categories, efficiencies and migrations are frozen.