Weekly debrief
2026.10.01
$D^0 \to K_{S,L}^0\pi$ control samples — Simone
-
Modify the helper function used to compute the constrained KL momentum so that it supports both reconstruction modes ( with KL and KS).
-
Plot $\Delta M$ and first check whether the required variable is already available among the ntuple branches.
$\tau \to K_S^0\pi\nu$ control sample — Arthur
Data–MC normalization
-
A deficit is observed in data relative to the total simulation. The discrepancy does not affect only the $q\bar q$ component.
-
Two effects may contribute:
-
the $q\bar q$ normalization;
-
a possible additional problem in the overall normalization of the prompt release-08 MCrd.
-
-
The normalization issue is still under investigation. In the meantime, the sample remains suitable for shape comparisons.
-
The $K_S^0$ mass correction has not yet been applied, nor the PID corrections
Control-sample suitability
-
The $\tau \to K_S^0\pi\nu$ control sample appears to be a good proxy for the signal.
-
Inset plots compare the BDT output and several input variables between the signal and the $K_S^0\pi+n\pi$ control sample.
-
Several validation distributions were shown, including $E_{\mathrm{ECL}}^{\mathrm{ROE}}$, which could potentially also be used for signal extraction.
-
The input features of the $q\bar q$ BDT were checked: it is importnat to show them as proof-of-agreement for the BDT CS validation
-
The inset plots should use a narrower ratio-axis range to show clearly that the data–MC differences remain within approximately 10% of unity.
-
The missing-energy distribution should be reweighted. The kinematic difference between the control sample and the signal is understood and is caused by the $K_L^0$ reconstruction inefficiency.
-
After reweighting, the two BDT-output distributions are expected to agree more closely.
-
-
Additional distributions were studied using different BDT selections, including a background-enriched region defined by BDT $<0.6$, in
ks0_cs_validation.
BDT-efficiency correction
-
The efficiency correction, computed as the double ratio of the efficiencies in data and MC, is approximately 1.5% at the selected $q\bar q$ BDT working point.
-
The current statistical precision is at the per-mille level.
-
The working strategy is to correct the BDT efficiency while keeping the associated uncertainty below 1%.
-
The BDT-efficiency definition should be rewritten explicitly as
$$
\varepsilon_{\mathrm{BDT}} =
\frac{N_{\mathrm{after\ BDT\ cut}}}
{N_{\mathrm{before\ BDT\ cut}}}.
$$ -
Applying background subtraction to the data control sample before computing the efficiency would introduce an additional uncertainty from the background-normalization factors. This coudl be consider as systamtic unceratinty contribution in the BDT efficiency correction
-
te overall systeamtic unceratinty i nthe BDT correction coudl come from taking the differnece of the correction derived with (nominal ) and without E_miss reweighting.
Possible data-driven selection
-
Suggested introducing a data-driven cut at the boundaries of the one-prong polar-angle distribution: it should be a safe selection because it does not bias the signal-side efficiency.
-
Test the effect of this one-prong angular cut.
Next steps
-
Adapt the constrained-KLM-momentum helper function to both the $K_L^0$ and $K_S^0$ reconstruction modes.
-
Check whether $\Delta M$ is already stored in the ntuple and produce the corresponding distribution.
-
Resolve the total-MC normalization discrepancy before interpreting the absolute data–MC yields.
-
Apply the $K_S^0$ mass correction.
-
Reweight the missing-energy distribution and verify whether the signal and control-sample BDT outputs then agree.
-
Modify the ratio-axis range in the inset plots to highlight deviations within 10% of unity.
-
Rewrite the BDT-efficiency figure using $N_{\mathrm{after}}/N_{\mathrm{before}}$.
-
Test the proposed one-prong polar-angle cut.
-
Finalize the BDT-efficiency correction and its uncertainty as the first priority.
-
Ask Michele on the Mattermost channel whether a similarly large data deficit was observed in the reconstructed $K_S^0$ samples.