23–28 Sept 2018
Europe/Rome timezone

Optimal RF-Photogun Parameters for the Compact XFEL Based on the New Linac-Injector Prototype

27 Sept 2018, 18:40
1h

Speaker

Mrs Yulia Kluchevskaia (NRNU MEPHI)

Description

The beam dynamics analysis of the RF-photogun as the LUCX facility at KEK, Japan, and new photo injector for the Russian 4th generation light source SSRS4 was done to chose the optimal length of the section and cell’s number and also to define optimal accelerating gradient and injection phase. The simulation of electrodynamics characteristics and fields distribution in the RF-gun based on 3.5-, 5.5- and 7.5-cell π-mode standing wave accelerating structure was done. The influence of the beam loading effect on the field amplitude and beam dynamics was the main purposes of study also. The beam dynamics simulation results will present in the report and optimal RF-gun parameters will discus.

Primary author

Mrs Yulia Kluchevskaia (NRNU MEPHI)

Co-author

Dr Sergey Polozov (NRNU MEPhI)

Presentation materials

There are no materials yet.