Gabor:
- 1phe analysis finished
- Assumption: Distance between peaks is fixed to the same quantity, use 24 runs (day of data) to create a banchmark histogram and compare each single run with that.
What is the effect of wrong 1phe? How to quantify
- In pedestal files there are channels with NaN and channels with 0
- NaN: there are data but it's not possible to identify the peak, not even by eye (like panettone channels)
- 0: there are no peaks
HDD:
- Test banchmark strategy with new runs using his script of fitting
Dora:
- Sobmitted jobs on Condor
- Small samples under analysis also background variables (this is for next week) - background generated from secondaries
- Digitalisation:
- Introduce energy trachsold
- TrackID: type of particle
- energy deposited per bar, per event. (if two particles hits the energy is summed)
- Use energy with only muons? Yes
- Cluster energy distributions.
- Fit cluster energy distribution (it should be clean enough) - for now do not apply clustering algorithm and only for muons.
- Provide cluster size distributions of the simulation as it is.
- Plot energy distributions of e, gamma, n and proton (4 more abundand secondaries that trigger the detector)
Andrea: If two particles hits the same particles, are counted twice? Double check what's plotted
Adythian:
- Fit with cluster energy using clusters involved in clusters, this should clean up the data
Actions:
- Alice: Send raw root file with only ADC counts